Rectangular Nitinol Spring for Neuro Guidewires

Rectangular Section Nitinol Radiopaque Spring for Neurovascular Guidewires

ZYTC Alloy manufactures precision flat-wire nitinol springs specifically engineered for neurointerventional cerebral micro-guidewires. Made from medical-grade Nitinol (ASTM F2063), this rectangular-section coil optimizes metal distribution within ultra-low profile catheters, delivering a critical balance of radiopacity, torque response, and superelasticity for navigating tortuous intracranial vessels.

Rectangular Nitinol Spring for Neuro Guidewires


📐 Precision Engineering: Why Rectangular Section?

Traditional micro-guidewires use round wire for distal coils. However, as neurovascular procedures push toward smaller and smaller vessel access, the limitations of round wire become apparent. Our rectangular nitinol springs solve these critical design challenges:

  • Improved Radiopacity: The flat-wire geometry increases the projected metallic surface area under X-ray, providing clearer visualization and precise intraoperative positioning without increasing the outer diameter of the coil.

  • Superior Shape Retention: Compared to round-wire coils, the rectangular profile offers higher resistance to shape loss. Once pre-shaped, the distal tip maintains its configuration stably while navigating complex cerebral vessels, minimizing springback and coil separation.

  • Optimal Wall-to-Lumen Ratio: The flat design allows the coil to sit closer to the micro-catheter’s inner wall, maximizing the inner lumen space for smoother device delivery.

  • Nitinol Superelasticity & Kink Resistance: Excellent superelastic behavior resists permanent deformation during repeated bending, ensuring smooth 1:1 torque transmission through tortuous anatomy.

 


Technical Specifications

Parameter Value / Detail
Material Medical-grade Nitinol (Nickel-Titanium Alloy)
Material Standard ASTM F2063 (Wrought Nickel-Titanium Alloy for Surgical Implants)
Cross Section Flat Rectangular Strip
Strip Width 0.02 mm (Customizable)
Strip Thickness 0.04 mm (Customizable)
Coil OD & Pitch Customized per guidewire design
Surface Finish Deburred, Clean-finished, Passivation available
Applications Neurointerventional cerebral micro-guidewires

Rectangular Section Nitinol Radiopaque Spring


ZYTC’s In-House Quality Verification

For neurovascular components, failure is not an option. We verify every batch of nitinol flat strip and finished springs in our in-house laboratory to ensure dimensional consistency and material integrity:

  • Microstructural Analysis: Using our Metallurgical Microscope, we inspect the nitinol strip and finished coil for micro-cracks, burrs, or inclusions that could lead to premature fatigue failure in the bloodstream.

  • Chemical Composition Verification: We use Direct Reading Spectrometry to strictly control the Ni/Ti ratio, ensuring the transformation temperature (Af) meets your specific design requirements.

  • Mechanical Testing: Our Universal Testing Machine verifies the superelastic recovery and tensile strength of the raw strip before micro-coiling.

 


Applications

  • Neurointerventional Guidewires: Distal radiopaque coil for cerebral aneurysm coiling and AVM treatment.

  • Intracranial Access: Navigating the highly tortuous and delicate vascular networks of the brain.

  • Micro-catheter Delivery Systems: Providing pushability and visualization in ultra-low profile systems.

 


Request a Quote or Sample

To discuss your custom nitinol coil requirements, please provide:

  1. Wire Dimensions: Strip width and thickness (tolerance requirements).

  2. Coil Geometry: OD, ID, pitch, and total length.

  3. Material Condition: Straight superelastic (SE) or shape memory (SME).

  4. Surface Requirement: Bare, passivated, or specific coating.

  5. Quantity: Prototype or mass production volume.

📧 Email: daisy@zytcsteel.com
📱 WhatsApp/WeChat: +86 17335753350

Scroll to Top